Extract - All Systems

Every effort must be taken to reduce personnel exposure to waste anesthetic gases. These self-contained recirculating air-cleaning systems capture air contaminants directly at the source, safely remove them, and then release clean air back into the room.

Bench Features:

  • Standard two-stage filtration system
    • High efficiency cartridge filter
    • Activated carbon
  • Two self-supported, articulating extractor arms, which can be flared at one end to make a "hood" up to 4.5" in diameter or decreased to make a nozzle as small as 2.0" in diameter. Each arm's reach is expandable up to 48" in length.
  • 3800 FPM duct velocity (one arm)
    2250 FPM duct velocity (two-arms)
    (A cap included to close off the unused inlet if only one arm is desired)
  • Low noise level - 100,000-hour motor life (typical) - Heavy-duty 14-gauge construction.
  • Baked-on polyurethane powder-coat finish

NEW Cabinet Features:

  • Standard two-stage filtration system
    • High efficiency cartridge filter
    • Activated carbon
  • Two self-supported, articulating extractor arms, which can be flared at one end to make a "hood" up to 4.5" in diameter or decreased to make a nozzle as small as 2.0" in diameter. Each arm's reach is expandable up to 48" in length.
  • 3800 FPM duct velocity (per arm)
    275 FPM velocity (at Grated Inlet)
    (A cap included to close off the unused inlet if only one arm is desired)
  • Low noise level - 66 dBA @ 6', 65 dBA @ 12'
  • 100,000-hour motor life (typical) - Heavy-duty 14-gauge construction.
  • CABINET: 18 gauge steel, polyurethane powder painted outside and inside.
  • CABINET DIMENSIONS:
    • 12.5"W x 12.5";H x 19.5"D in horizontal position
    • 12.5"W x 19.5"H x 12.5"D in vertical position
  • WEIGHT: Approximately 30 lbs. (Plus additional weight for filter options.)
  • BLOWER: 350W, 2.8 amps, 120/1/60, 2000 RPM, variable speed control, and poser cord with plug.
  • RATED FAN PERFORMANCE: 350 CFM @ 0.5" E.S.P., 240 CFM @ 2.0" E.S.P., 100 CFM @ 2.75" E.S.P.

 

Replacement Filters and Refills for Old Style Mobile Extract - All Cabinet

 


Primary Filter adsorption module for Original Extract - All
Item Number: 933106 - High-capacity adsorption filter. Refillable with activated carbon.

 


Secondary Filter adsorption module for Original Extract - All
Item Number: 933107 - High-capacity adsorption filter. Refillable with activated carbon.


Item number: 933108 Primary filter refill
Item number: 933109 Secondary filter refill
 


Extract - All Bench
Item Number: 933101 - Comes with two sets of mounting brackets to attach easily to table or bench top, with primary stage filter extending above or below.




NEW Extract - All Cabinet
Item Number: 933105 - The portability of this system makes it ideal to use in hard to reach places and for moving between locations. The primary stage filter is located inside the cabinet. This model also accepts an optional secondary activated carbon, refillable adsorption module.


NEW Cabinet Replacement Filter Set
(Includes Carbon Filter & Pleated Filter)
Item Number: 933120
Click here for a close up of the Carbon Module

 
  Home | About | Catalog | Knowledge | Links | Contact Us Copyright © VetEquip, Incorporated